Product description:
◆ The ductless air-purifying fume hood is specially designed to protect the safety of laboratory personnel during the experimental
operation. It can effectively prevent laboratory operators from inhaling and swallowing some toxic, curable or unknown toxic
chemicals The ductless air-purifying fume hood sucks up the toxic and harmful gases generated in the laboratory, passes the
high-efficiency filter system to absorb the filters, and forms clean air to return to the room. The stable surface wind speed forms
a natural barrier to isolate people. Continuous operation of chemicals with operators and fume hoods can purify the air in the
laboratory, thereby ensuring the safety of operators and providing safe occupational health and health protection for laboratory
personnel.
Excellent:
◆ There is no need to install pipeline engineering, the installation is convenient, the exhaust gas is not discharged, and the new type is
environmentally friendly.
◆ The top can be equipped with a filter module system according to the experimental needs to meet a variety of different experiments.
◆ Advanced modular filtration technology completely adsorbs and filters harmful gases, particulate dust and other substances
generated in the experiment.
◆ It can be placed on a table or equipped with a mobile wheel seat, which is convenient and flexible and suitable for any complex
experimental location.
Product Description:
◆ The main material of clean air type fume hood without pipeline is ≥ 1.2mm galvanized steel plate with anti-corrosion coating.
◆ The front window is made of acrylic plate ≥ 6mm, transparent, excellent weather resistance and chemical resistance.
◆ The epoxy resin table has superior chemical stability and strong corrosion resistance.
◆ The cabinet body adopts inclined angle design, which is convenient to operate and more humanized.
◆ LED LCD, HD display, beautiful panel, easy to operate.
◆ The temperature and humidity monitoring system can display the temperature and humidity in the operation area in real time and set
the alarm value.
◆ Monitoring system: monitor the operation status and failure alarm of the fan, and effectively control the leakage of toxic substances.
Set the filter saturation alarm value, monitor the filter saturation status, and timely remind the user to replace the filter to ensure the
safety of product use.
◆ CPU controllable system: CPU control panel, displaying basic operation information of the device.
◆ Ultra quiet fan, stable service life ≥ 60000 hours (about 6 years).
◆ It does not need to exhaust the air in the laboratory, does not affect the use of air conditioning, and can save a lot of energy.
Model and technical parameters:
Index / model | JQ-1000 |
External dimension (mm) | 1000x700x1900(L*D*H) |
Internal dimension (mm) | 950*600*850(L*D*H) |
Air handling capacity (m3 / h) | 850 |
Wind speed regulation (m3 / h) | 0~850 |
Fan life (H) | ≥60000 |
Fan power (W) | 45W |
Fan noise (DB) | ≤58 |
Average surface wind speed (M / s) | O.3~0.6 |
Filter (piece) | 1 prefilter, 2 molecular filters and 1 HEPA filter |
Rated voltage (V) | 210~242 |
Type of operation hole | Optional (triangle, ellipse, trapezoid) |
Operating environment (℃) | 0~40℃ |
Lighting LED | 20W |
Uv germicidal lamp | 20W |